论文部分内容阅读
我公司矿山分厂新区破碎工段骨料线自2014年8月份投产后,生产稳定,设备运转相对稳定。但是10月2日2号振动筛(型号2YK-2160)激振器轴承温度开始飚升,最高温度达到86℃,与1号振动筛(型号相同,工况相同)轴承测量温度差距较大,最高可达16℃,平均在10℃左右。1轴承温度升高的原因分析轴承温度升高时,一般的做法就是补充润滑脂进行降温。但是操作人员发现温度升高时补充2号锂基
After the production of the aggregate line of the crushing section in the new district of the Company’s mine branch since August 2014, the production has been stable and the equipment operation has been relatively stable. However, on October 2, No. 2 shaker (Model 2YK-2160) vibration began to soar the bearing temperature, the maximum temperature reached 86 ℃, and No. 1 shaker (the same model, the same working condition) bearing temperature measurement of the larger the gap between the maximum Up to 16 ℃, an average of about 10 ℃. A bearing temperature rise analysis Bearing temperature rise, the general practice is to add grease to cool down. However, the operator found that when the temperature increases, add lithium 2 base