本文分析了《建筑工程施工现场消防安全技术规范》(GB50720-2011)推行所面临的困难,并提出相应的解决建议,特别是在临时消防给水系统与应急干式消火栓系统的推广相结合、临时消防水池的归处及临时消防水源选取等方面。此外还针对脚手架及建筑外墙在施工时容易发生火灾这一问题,提出了“临时垂直水带”和“消防一体式脚手架”等临时消防给水设计的思路。
This article analyzes the difficulties in the implementation of “Technical Code for Fire Safety in Construction Site” (GB50720-2011), and puts forward corresponding solutions. In particular, combining the temporary fire-fighting water supply system and the promotion of emergency dry-type hydrant system, Fire pool at the home and temporary fire water source selection and so on. In addition, aiming at the problem that the scaffolding and the building external wall are prone to fire during construction, the idea of temporary fire water supply design such as “temporary vertical water band” and “fire integrated scaffolding” is put forward.