论文部分内容阅读
在规定烟气再循环率确切含义的前提下,利用简化的烟气流动模型推导出再循环率的计算公式。经徐州电厂400吨/时锅炉烟气再循环调温试验证实,所提出的测定和计算方法都具有方便简单与结果可信程度高等特点。文章最后还讨论了再循环率的连续监测问题。
On the premise of specifying the exact meaning of flue gas recirculation rate, a simplified flue gas flow model is used to derive the formula for calculating the recirculation rate. The Xuzhou Power Plant 400 tons / hour boiler flue gas recirculation thermostat test confirmed that the proposed measurement and calculation methods are simple and convenient and the credibility of the results with high characteristics. Finally, the article also discusses the continuous monitoring of the recycling rate.