论文部分内容阅读
探讨吸入物变应原过筛试验(Phadiatop)和总IgE(TIgE)检测对变应性鼻炎诊断的意义。应用CAP(帽式)System检测鼻炎患者的吸入物变应原过筛试验(Phadiatop)和总IgE(TIgE)。对58例变应性鼻炎及22例非变应性鼻炎均进行Phadiatop、TIgE检测。Phadiatop的灵敏度(0.90),特异性(0.95),准确度(0.92)均高于TIgE。结果表明Phadiatop是变应性鼻炎灵敏、特异、准确的过筛试验
To investigate the significance of inhalation allergen screening test (Phadiatop) and total IgE (TIgE) in the diagnosis of allergic rhinitis. The CAP (Cap) System was used to detect inhalation allergen screening tests (Phadiatop) and total IgE (TIgE) in patients with rhinitis. 58 cases of allergic rhinitis and 22 cases of non-allergic rhinitis were Phadiatop, TIgE detection. Phadiatop’s sensitivity (0.90), specificity (0.95), accuracy (0.92) were higher than TIgE. The results show that Phadiatop allergic rhinitis sensitive, specific and accurate screening test