论文部分内容阅读
本文从理论上分析了IEC 106公报第22款修正案中所规定的无用辐射测量场地的衰减量,推导了它的计算公式,并用微机对典型场地的衰减量作了计算,计算结果表明与IEC日本国委员会80年10月提交12A小组的意见书基本一致。
This paper theoretically analyzed the attenuation of the unwanted radiation measurement site stipulated in the amendment to IEC Publication 106, deduced its calculation formula and calculated the attenuation of a typical site with a microcomputer. The calculation results show that with IEC Submission to the Panel 12A by the Japanese National Committee in October 1980 was basically the same.