Effect of enhanced supply air filtration in buildings on protecting citizens from environmental radi

来源 :建筑模拟(英文版) | 被引量 : 0次 | 上传用户:znzlwzkp
下载到本地 , 更方便阅读
声明 : 本文档内容版权归属内容提供方 , 如果您对本文有版权争议 , 可与客服联系进行内容授权或下架
论文部分内容阅读
The effect of enhanced filtration on protection citizens staying indoor against airborne radionuclides released during nuclear core melt accidents was determined by field measurements using outdoor particles as simulants. An electrically enhanced filter was installed in the HVAC system of an office building and its removal efficiency for particles was altered by using a separate particle charging section in power on and off positions. The effect of air filtration on indoor particle concentrations was determined by using an automated measurement system which was continuously sampling from the outdoor air, filtered supply air and exhaust air. With the aid of the measured outdoor and modelled indoor concentrations the indoor/outdoor ratio of particles of outdoor origin could be accurately determined. External charging of the particles increased the electret filters removal efficiency for 0.4 μm size particles from 60% to 95%, resulting in decrease of the average I/O ratio of the same size particles from 0.67 to 0.40. Despite the high improvement in the supply air filtration efficiency the indoor concentrations decreased only modestly which is likely due to the leaky construction of the building, demonstrating the detrimental effect of air infiltration on the protection provided by buildings against outdoor airborne hazards. Practical implications: The developed method allows quantification of the key parameters affecting the protection of buildings against outdoor contaminants, thus allowing accurate estimation of size resolved indoor to outdoor ratios for fine particles. The electrically enhanced filter can remove effectively also submicron particles thus reducing the occupant exposure to outdoor hazardous or harmful materials. Bestresults can be achieved with airtight buildings.
其他文献
为克服海水反渗透(SWRO)脱盐技术存在的预处理污泥体积大和总体水回收率低两大问题,提出了一种新型的混合反渗透-正渗透(RO/FO)系统,在MATLAB中开发了RO/FO混合系统的软件,并
以高比表面积、纳米尺寸ZIF-8作分散相、以Ultem(R) 1000作连续相,通过干—湿相转化纺丝法分别制备了Ultem(R) 1000和ZIF-8/Ultem(R) 1000中空纤维气体分离膜,研究了ZIF-8对
Aquatic centres are unlike any other type of buildings in terms of energy and water consumption.Aquatic centres can expend around seven times more energy for ev
经典的抗原递呈理论认为,抗原递呈细胞(antigen presenting cell, APC)在加工处理和递呈外源性抗原及内源性抗原时存在两种不同的途径,即分别为MHCⅡ类分子限制性途径和MHCⅠ
This paper presents a numerical study on the required momentum flux ratio to prevent air curtain breakthrough in case of cross-curtain (i.e. cross-jet) pressure
肿瘤抗原-线粒体蛋白12(TumorAntigen-MitochondrialProtein12,TAMP12)是本实验室应用SEREX(SerologicalanalysisofrecombinantcDNAexpressionlibrary,SEREX)技术从人卵巢癌cDN