P.H.希普 43023,俄亥俄洲,格兰弗利、俄温司/科灵技术中心 G.D.梅克塞尔 55455,明尼苏达洲,明尼波尼斯,明尼苏达大学地下空间中心 J.W.兰门塞 55455,明尼苏达洲,明尼波尼斯,明尼苏达大学机械工程系为了探明推广土掩蔽体的设计原则对大工业厂房的优点,明尼苏达大学拟订了一个程序,并在进行测定和分析工作。从1978年起在校园内的一个土掩体建筑物的测量中,采用了为分析土掩蔽体建筑包壳而发展起来的瞬态有限差分热传递计算机程序,说明了并实验验证
PH Shipw 43023, Ohio State, Glenforey, AWS/Keling Technical Center GD Meckel 55455, Minnesota, Minneapolis, University of Minnesota Underground Space Center JW Ramensay 55455, Minnesota, Niponis, Department of Mechanical Engineering, University of Minnesota To explore the advantages of design principles for the promotion of earth shelters for the advantages of large industrial plants, the University of Minnesota has developed a procedure and is conducting measurements and analysis. Since 1978, in the measurement of an earth bunker building on campus, a transient finite difference heat transfer computer program developed for the analysis of earth sheltering building envelopes was used to demonstrate and verify the experiment.