Fast reconstruction in fluorescence molecular tomography using data compression of intra- and inter-

来源 :ChineseOpticsLetters | 被引量 : 0次 | 上传用户:qq13545197270
下载到本地 , 更方便阅读
声明 : 本文档内容版权归属内容提供方 , 如果您对本文有版权争议 , 可与客服联系进行内容授权或下架
论文部分内容阅读
In order to improve the reconstruction accuracy in fluorescence molecular tomography (FMT), a common approach is to increase the number of fluorescence data or projections. However, this approach consumes too much memory space and computational time. In this Letter, a data compression strategy that involves the removal of the redundant information from both intra- and inter-projections is proposed to reduce the dimension of the FMT inverse problem. The performance of this strategy is tested with phantom and in vivo mouse experiments. The results demonstrate that the proposed data compression strategy can accelerate the FMT reconstruction nearly tenfold and almost without any quality degradation.
其他文献
报道了一台小型实验室规模的光解碘原子激光振荡-二级放大系统,它可提供脉宽1ns~2μs、脉冲能量几十mJ~10J、峰值功率~10MW的单模输出.文中着重讨论了该系统的设计、各种选模、脉冲发生技术及其工作特性.
期刊
期刊
期刊
构建了无透镜傅里叶变换数字全息实验系统, 实现了对一组生物样品特别是活体细胞的高保真度定量相衬成像。系统的简单性在于其数值再现过程只需直接对全息图进行一次快速傅里叶变换, 而对由此引入到相位像中的畸变, 则采用两步相减法予以校正。成像物体首先选用家蚊口器和洋葱表皮细胞的生物教学样片, 进而使用无标记的活体宫颈癌细胞。实验中, 不仅观察到了静态生物样品清晰的形态, 而且观察到活体细胞形态的动态变化, 充分表明了数字全息显微术应用于生物样品相衬成像的有效性。
A numerical method providing the optimal laser intensity profiles for a direct-drive inertial confinement fusion scheme has been developed. The method provides an alternative approach to phase-space optimization studies, which can prove computationally ex
本文首次报道室温下测量的分子束外延生长的ZnSe-ZnTe应变层超晶格的远红外反射谱.得到了ZnSe、ZnTe横光学声子摸.用长波长超晶格介电理论和多层吸收薄膜理论进行曲线拟合,确定Ⅱ-Ⅵ族ZnS、eZnTe材料的一些基本材料参数,如横光学声子频率、模衰减常数、模振荡强度、高频介电常数等.本文首次报道这些参数.
本文分析了散斑错位照相术的空间频率成分,得到条纹纯暗区的散斑结构等同于两个半圆透镜散斑像场非相干迭加的结论,该结论有别于Y.Y.Hung的结果。还使用记录光瞳的方向孔径与散斑谱晕周界两个概念,分别计算了条纹纯亮、暗区域所对应的谱晕周界方程。对以上结论进行了实验验证,并附带提出了带通滤波器的最佳图形。该结果不仅可用于进一步改善错位照相条纹的质量,也对电子散斑错位干涉仪的研究有益。
期刊
国际激光器系统公司最近研制成一种实验室激光器系统,它能由一个10毫微秒脉冲提供10兆瓦之功率。这种实验系统由两个单位合作制成:国际激光器系统公司提供倍频Nd:YAG激光器泵浦源,激光能量公司提供染料激光头。这种347型染料激光头采用一个短光腔和半纵向结构,从而获得有效的能量转换。试验时使用若丹明6G。输入为532毫微米、300毫焦耳的Q调制脉冲,获得了10亳微秒、100毫焦耳之输出,脉冲重复率为5微微秒。大约在550~600毫微米输出是可调的,发射峰值在570毫微米处出现。
期刊
We are very pleased and honored to have the opportunity to dedicate a series of papers to our dear friend, mentor and colleague, Valery V. Tuchin, to commemorate the occasion of his 70th birthday. Prof. Tuchin is one of the founders of the Biophotonics fi
期刊
美帝国家航空和宇宙航行局设计了一种激光束瞄准系统,能使氩激光束对准月球上被照明表面上的特定点。这种系统将准直激光束,并以极高的角跟踪精度,使它射向月球表面上的物体。经修改之后,能用这种系统精确跟踪导弹和卫星。这系统包括一台长焦距反射式望远镜,在望远镜的焦平面上安置了一个分束器。激光束通过一面会聚透镜聚焦到分束器上的一个小孔上,然后通过望远镜射向目标地区。分束器的作用是把出射光束和进来的导引光束(从望远镜来的月光)分开。