陶庄矿随着生产水平及安全质量要求的提高,目前使用的最大风机(70B_2—21—24~#风机,电动机为570瓩、740转/分)已不能满足要求。按该风机产品样本介绍的性能,工作制度为静压力360毫米水柱、风量6000米地~3/分、静效率0.65,故电机负荷为544瓩。由于风机启动性能不好,故570瓩电机不能满足启动要求。经对该风机进行深入调查研究后认为:从风机本身看,网路只是外因,本机是内因,外因通过内因起作用。如果风机效率低,无论怎样花费气力调整网路,通风费用仍有较大浪费。目前在东风井使用的70B_2—21—18~#风机,风量只有4300米~3/分,但负荷已达到520瓩就是个证明。由于风机
Taozhuang mine with the production level and safety and quality requirements increase, the largest fan (70B_2-21-24 ~ # fan, the motor is 570 瓩, 740 rev / min) can not meet the requirements. According to the fan product sample describes the performance, work system is static pressure 360 mm water column, the air volume of 6,000 meters to 3 / min, static efficiency 0.65, so the motor load of 544 瓩. As the fan start performance is not good, so 570 瓩 motor can not meet the start requirements. After in-depth investigation of the fan that: from the fan itself, the network is only external, the machine is internal, external factors through the internal work. If the fan is inefficient, no matter how hard it is to adjust the network, there is still a big waste of ventilation costs. At present, the 70B_2-21-18 ~ # used in Dongfeng wells has a wind volume of only 4,300m ~ 3 / min, but the load has reached 520 瓩, which is a proof. Due to the fan