二维及实时三维超声心动图评价右心室容积的准确度研究

来源 :中国超声医学杂志 | 被引量 : 0次 | 上传用户:sanshao
下载到本地 , 更方便阅读
声明 : 本文档内容版权归属内容提供方 , 如果您对本文有版权争议 , 可与客服联系进行内容授权或下架
论文部分内容阅读
目的 (1)评价实时三维超声心动图测量右心室容积的准确度;(2)探讨二维超声心动图测量右心室容积的方法及其准确度。方法 27例健康志愿者,在24 h内进行常规二维超声心动图(2-DE)、实时三维超声心动图(RT-3DE)及心脏核磁共振(cMRI)检查。2-DE计算右室容积采用Simpson法、对切半椭圆体法和双平面面积-长度法(简称双平面法);RT-3DE采用三平面成像法(Tri-plane)及Tom-Tec 4D RV-Function CAP进行容积计算(结果分别记为RT-3DEV1、RT-3DE V2)。cMRI图像采用Argus软件计算容积。将2-DE与RT-3DE测量的结果与cMRI结果对比研究。结果 Simpson法、对切半椭圆体法及RT-3DEV1所得结果低估RVEDV及RVESV(P<0.001),差异有统计学意义;双平面法及RT-3DE V_2结果对RVEDV及RVESV有一定的高估或低估(P>0.05),但差异无统计学意义。相关分析表明,Simpson法及RT-3DEV_1测值与cMRI测值相关性较差(RVEDV,r=0.37,0.38;RVESV,r=0.35,0.38)。RT-3DE V_2、对切半椭圆体法及双平面法测值均与cMRI测值高度相关,(RVEDV,r=0.72,0.73,0.85;RVESV,r=0.60,0.73,0.80)。Bland-Altman分析显示,RT-3DE V_2及双平面法与cMRI的右室容积测值的平均差值更小、一致性界限更窄。结论 (1)RT-3DE采用Tom-Tec 4D RV-Function CAP软件进行分析能够较准确的测量右心室容积;(2)二维测量方法中,双平面面积-长度法能够较准确测量右心室容积。 Objective (1) To evaluate the accuracy of real-time three-dimensional echocardiography measurement of right ventricular volume; (2) To explore the method and accuracy of two-dimensional echocardiography measurement of right ventricular volume. Methods Twenty-seven healthy volunteers underwent routine two-dimensional echocardiography (2-DE), real-time three-dimensional echocardiography (RT-3DE) and cardiac magnetic resonance imaging (cMRI) within 24 hours. 2-DE was used to calculate the volume of the right ventricle using the Simpson method, the cut semi-ellipsoid method and the double plane area-length method (referred to as biplane method); RT-3DE using the three plane imaging method (Tri-plane) and Tom-Tec 4D RV -Function CAP volume calculation (results were recorded as RT-3DEV1, RT-3DE V2). CMRI images are calculated using Argus software. The results of 2-DE and RT-3DE measurements were compared with cMRI results. Results The Simpson’s method underestimated the RVEDV and RVESV (P <0.001), and the difference was statistically significant for the results of the cut-and-half ellipsoid method and RT-3DEV1. The biplane method and the RT-3DE V_2 result had a certain overestimation of RVEDV and RVESV Or underestimated (P> 0.05), but the difference was not statistically significant. Correlation analysis showed that the correlation between Simpson and RT-3DEV_1 was not correlated with cMRI (RVEDV, r = 0.37,0.38; RVESV, r = 0.35,0.38). The results of RT-3DE V_2, cut semi-ellipsoid and biplane were highly correlated with cMRI (RVEDV, r = 0.72,0.73,0.85; RVESV, r = 0.60,0.73,0.80). Bland-Altman analysis showed that RT-3DE V_2 and the biparietal method and cMRI RVG mean value of the difference is smaller, narrower consistency of the boundaries. Conclusions (1) The RT-3DE can accurately measure the RV volume with Tom-Tec 4D RV-Function CAP software. (2) The biplane area-length method can accurately measure the RV volume .
其他文献
本报讯(记者 王伟杰 通讯员 张惠 赵侗芳)昨日上午,常德市产业发展基金发布暨签约活动在柳叶湖畔举行。当天共发布产业发展基金100亿元,配套200亿元信贷授信,形成100亿元加200亿元
报纸
本文回顾分析了围绝经期动物模型研究的最新进展,比较了目前常用动物模型的优点和劣势,分析表明对于围绝经期动物模型制备方法的优劣判断,不但要从成本方面考虑,更重要的是卵
良好的平衡功能与人们的日常生活、社交及娱乐活动等密切相关。对于脑卒中等偏瘫患者而言 ,恢复步行功能是他们最迫切的希望之一 ,而平衡能力的控制对于步行功能的恢复至关重
隧道渗漏水养护是对于维持隧道的使用环境和控制管理费增加的重要课题。另外,漏水造成衬砌结构的损害,也引起隧道紧急补修的问题.渗漏水养护措施作为确保高速公路工程施工质
介绍《诗经》多译本平行语料库的创建过程,重点探讨中英文语料的选择,语料的分词、标注以及对齐等操作的具体方案,力求为《诗经》的英译研究拓展出全新的视角和途径,以期促进
个人数据是个人信息在网络环境中的新形式,兼具人格和财产双重属性。但无论是将其视作纯粹人身权、财产权,还是认可其拥有双重属性,都没有超越私权路径的考量,都忽略了大数据
设计了一种滑轮式井盖提升工具,包括底座部分、支撑部分和提升部分等。该工具可适合于诸多场合不同大小的井盖提升,具有操作省力、结构简单、携带方便、功能强、成本低、易推