Model eye tool for retinal optical coherence tomography instrument calibration

来源 :JournalofInnovativeOpticalHealthSciences | 被引量 : 0次 | 上传用户:LXM302
下载到本地 , 更方便阅读
声明 : 本文档内容版权归属内容提供方 , 如果您对本文有版权争议 , 可与客服联系进行内容授权或下架
论文部分内容阅读
Optical coherence tomography (OCT) has been extensively used as noninvasive tool for biological tissues owing to its three-dimensional imaging ability and high axial resolution. OCT quality assurance is vital in these occasions to keep the reliability and accuracy in medical diagnosis. It is necessary to develop a calibration tool for OCT product manufacture, calibration, and quality control. A practical tool is demanded in the OCT quality control and calibration of OCT. So far, there is no such a practical tool that can test all the key parameters of OCT. We design and fabricate a model eye tool, which has this function. The model eye comprises a doublet lens, a single filament, a piece of glass plate and the microsphere-embedded phantom. The doublets lens is bonded by two pieces of planoconvex lenses in the plane position. The first lens focuses parallel light onto the rear surface of the second lens. The rear surface marked with concentric circles serves as retina to measure the angular field of view (FOV). The small flat surface on the peak of the second lens is used to test signal to noise ratio (SNR). The single filament with 125 μm diameter is used to check the co-alignment of preview and OCT scan. The empty chamber between the small plane of the second lens and the first surface of glass plate is used to measure the depth scaling of the OCT. The microspheres of 1 μm diameter distributed uniformly in the phantom, which can test the lateral and the axial resolution of OCT equipment. Experimental results are presented to show the validity of the proposed tool. It is shown that the tool is able to be used in the calibration and quality control of retinal OCT.
其他文献
We propose and demonstrate two types of narrowband multi-channel filters: transmittance-integrated narrow-bandpass filter arrays and reflectance narrowband multi-channel filters. We develop a combinatorial etching technique possessing 32 elements on a sin
利用Matlab对光纤表面等离子共振(SPR)传感器进行仿真, 得知选用纤芯直径为400μm或600μm的石英光纤作为SPR传感器具有良好的折射率检测特性。实验选用宽带光源作为入射光, 在波长550~800nm范围内, 应用Matlab仿真分析了不同折射率样品的共振波长与透射率的关系, 与实验数据对比表明, 仿真结果与实验结果相一致。
期刊
分析了实心角锥棱镜对任意方向入射光的偏振态的影响,同时考虑振幅的变化,给出角锥棱镜的琼斯矩阵表达式,文中计算了当光线平行于角锥棱镜对角线方向入射时角锥棱镜的琼斯矩阵的具体数据,同时对不平行的一些典型的情况也进行了计算,所有结果均在实验中得到证实.
通过测量声光调制器衍射的激光束的布喇格角,可以对调制器晶体作定性检验。
期刊
本文讨论了高压氢气中在正向散射反馈下后向喇曼放大的异常饱和特性,并且和理论模型作了比较。
期刊
本文介绍一种精确测定光学材料反射、透射谱的装置。采用快速旋转的导光纤维交替对入射光束及反射光束或透射光束采样,利用反馈控制使入射光束产生的光电流维持常数,避免被测信号之间进行除法的困难。在410.0~650.0nm的波段测量,相对精度小于2%自动绘制整个谱所需时间仅二分钟。
期刊
The nonlinear optical (NLO) and optical limiting (OL) properties of three new structures of organic NLO guest–host Poly(N-vinylcarbozole)/disperse orange 3 (PVK/DO3), PVK/disperse orange 13 (PVK/DO13), and PVK/disperse orange 25 (PVK/DO25) as a solution a
射线源和探测器作相对平行直线运动的计算机层析成像扫描系统(OPLCT)结构简单,成本低,易于实现便携或可移动的应用需求。该扫描方式的前期研究采用顺序子集-同时迭代重建算法,该算法存在图像重建时间长、不能实现快速成像等问题。从傅里叶积分定理出发,推导OPLCT滤波反投影(OPLFBP)图像重建算法。构建的一次直线扫描(1T)图像重建模型属于有限角问题,OPLFBP算法不能完全重建出目标图像;进一步提
Accepted 6 December 2013 Published 5 February 2014 This work presents the use of extended Modified Lambert Beer (MLB) model for accurate and continuous monitoring of percent blood carboxyhemoglobin (COHb) (SCO) and oxyhemoglobin (OxyHb) saturation (SO