论文部分内容阅读
压力消毒柜夹层除锈法,国内尚未见有报道。我院使用上海产SS12型压力消毒拒已12年整。近来发现上升温度和压力缓慢,最高温度只能上升到110度、压力0.5磅,而且需要90分钟。这样的温度和压力达不到灭菌制剂技术的要求。我们应用盐酸清洗液对压力消毒柜进行除锈清理,取得良好效果。经清洗后只需30分钟,温度上升到122度、压力可达到1.5磅(汽源压力不变)。
Pressure disinfection mezzanine derusting method, there have been no reports of domestic. Shanghai hospital use SS12 pressure sterilization has refused 12 years. Recently, it has been found that ascent temperature and pressure are slow, the maximum temperature can only rise to 110 degrees, the pressure is 0.5 lbs, and it takes 90 minutes. Such temperatures and pressures do not meet the requirements of sterilization formulation technology. We use hydrochloric acid cleaning liquid pressure disinfection cabinet rust cleaning, and achieved good results. Only 30 minutes after cleaning, the temperature rises to 122 degrees, the pressure can reach 1.5 pounds (steam source pressure unchanged).