反应堆冷却剂泵电机漏油原因分析

来源 :核动力工程 | 被引量 : 0次 | 上传用户:caiaikai
下载到本地 , 更方便阅读
声明 : 本文档内容版权归属内容提供方 , 如果您对本文有版权争议 , 可与客服联系进行内容授权或下架
论文部分内容阅读
针对某核电厂主泵电机轴承漏油问题进行原因分析。分析认为,电机运行时产生的“风扇”效应、轴承箱尺寸和储油量限制、未设置有效的润滑油凝结收回装置等是下导轴承润滑油、油气泄漏的主要原因。经计算流体动力学(CFD)分析表明,通过在下导轴承上方设置隔板、密封,在上、下轴承上方增设油气凝结装置及回油通道,可在不改变电机现有主体结构和轴承内部构件的基础上,进一步改善电机轴承漏油问题。 Cause Analysis of Leakage of Main Pump Motor Bearing in a Nuclear Power Plant. The analysis shows that the “fan” effect, the size of the bearing housing and the oil reserve caused by the motor running are not the main factors that cause the leakage of lubricating oil and gas in the dowel bearing. Computational fluid dynamics (CFD) analysis shows that by installing a bulkhead above the dowel bearing and sealing, an oil-gas condensing device and an oil return passage above the upper and lower bearings can be provided without changing the existing main structure of the electric motor and internal components of the bearing On the basis of further improve the motor bearing oil leakage problems.