例一:一台286微机,使用数年后,突然出现无法启动的故障。即开机自检时,显示器显示出英文的“键盘错误”字样,然后停止自检,键盘操作完全失效。由于在其它机器上验证了该机键盘是好的,所以,原机使用者曾认为是键盘接口电路有问题。笔者在检查此机时,发现主板上机内电池已失效漏液,且已流淌到附近的印刷线路板上(原机为卧式机芯),故怀疑是电池液把线路腐蚀断了。用万用表欧姆档测量被电池液污染的几根线,发现确有一根不通,查其走向,正是通往键盘的一根线。当另外用细导线把该线路断开的两端接通之后,开机检验,一切正常。为了彻底消除后患,用两节五
Example 1: A 286 computer, after a few years of use, suddenly failed to start the fault. That POST, the display shows the English “keyboard error” message, and then stop self-test, the keyboard operation completely failed. As the other machines verify that the keyboard is good, so, the original user once thought there was a problem with the keyboard interface circuit. When I check this machine, I found the motherboard on the machine battery has failed leakage, and has been flowing to the nearby printed circuit board (the original machine is a horizontal movement), it is suspected that the battery fluid to the circuit corrosive. Measured with a multimeter Ohm file battery fluid contamination of several lines, found that there is indeed a barrier, check its direction, it is the key to the keyboard. When the other ends with the fine wire to disconnect the line connected to the boot test, everything is normal. In order to completely eliminate the troubles, with two five