论文部分内容阅读
自动喷水灭火系统有报警阀的主排水试验放水装置、水泵试验放水装置和末端试水装置三大试验装置,是自动喷水灭火系统中重要的装置,在系统调试、维护、保养中发挥着不同的作用。三大试验装置的设置部位、设置目的和设置要求是完全不同的。文章介绍了自动喷水灭火系统三大试验装置设置的部位、目的和设置要求,为设计、施工、维护系统提供了可行的方法。
Automatic sprinkler system alarm valve with the main drainage test water release device, the water pump test device and the end of the water test device three test devices, automatic sprinkler system is an important device in the system debugging, maintenance, maintenance play Different roles. The setting of the three test devices, set the purpose and set requirements is completely different. The article introduces the location, purpose and setting requirements of the three test devices of automatic sprinkler system, and provides a feasible method for the design, construction and maintenance of the system.