论文部分内容阅读
1995年4月17日,我县活龙区水电管理站安排本站电工姚学友去整修一根因拉线松驰而倾斜的10kv线路转角杆。 姚到达现场后,一人进行紧拉线的工作(此时10kv线路仍带电运行)。姚将紧线钳的收紧绳一端固定在地锚上,在既未用紧线钳口夹住拉线,又未打临时拉线的情况下,即松开拉线下把,用手抓住拉线准备将其拉拢紧线钳夹住。由于当时正下着牛毛细雨,姚抓着拉线因“麻电”而跌坐在地,手自然松开,拉线弹出,其上端靠近横担处弯曲部分接触到10kv弓子线而带电,另一端拖在地上,发出“咝咝”的放电声。姚学友明知拉线已带电,拿着一支令克棒准备去勾开拉线,当走到接近拉线的地方,即因跨步电压触电而扑倒在拉线上,当即触电死亡。 经分析,造成此次事故的原因: 1、区电管站在线路维修工作中
April 17, 1995, Huonong County hydropower station management station electrician Yao Xueyou to renovate a due to pull the slant and inclined 10kv line corner. Yao arrived at the scene, one of the tight pull line work (this time 10kv line is still live run). Yao will be tight wire clamp tighten the rope at one end fixed to the anchor in both without tight wire clamp jaws, and did not hit the temporary pull the case, that is, under the release of the pull line, hold the cable ready by hand Pinch it with wire clamp. Because at that time under the drizzle, Yao grabbed the pull line due to “Ma electric” and fell to the ground, the hands naturally loosen, pull the pop-up, the upper end of the cross-beam at the curved part of the contact with 10kv bow line and the other end of the drag On the ground, a “咝 咝” discharge sound was issued. Yao Xueyou know that the cable has been charged, holding a make grams stick ready to open the cable, when approached the cable place, that is, because of the voltage step-by-step and threw himself on the cable, immediately electrocuted death. After analysis, the reasons for the accident: 1, the district power station line maintenance work